Track-it QA data management platform

  • Web-based application for quick access to all your QA data from anywhere in your network using desktop or mobile devices
  • Online or offline QA report processing, e.g., in treatment rooms without wireless network access
  • User-defined protocol templates to customize Track-it to the specific needs of your QA workflows
  • Full compliance with all major QA standards, including AAPM TG-142
  • Traceable documentation of all steps in your QA workflow, such as data entry, modification and reporting
  • Trend analysis over time and across multiple measurement or treatment devices with versatile display options
  • Digital logbook to store and retrieve entries and attached service documents for your radiation devices, e.g., manuals, service reports or images
  • Remote and on-site services for greater productivity right from the start

RUBY Modular QA Phantoms

RUBY Modular QA Phantoms Base phantom or head phantom. Multiple inserts. System QA. Linac QA. Patient QA.

System QA

Choose the System QA insert for comprehensive end-to-end testing with one single insert. 

  • MRI visibility in all commonly used sequences (T1, T2 and FLAIR at 1.5 T) – no additional components required
  • ICRU-based tissue-equivalent materials (brain, lung, bone) for verification of dose calculations at different tissue densities
  • CT and MRI cavities for accurate verification of the CT/MRI image fusion algorithm of treatment planning systems
  • Point dose measurements with different detector types using the same insert

Linac QA

Perform alignment checks of the entire system, including conventional as well as 6D couches, with the Linac QA insert.

  • System alignment and isocenter checks  with one single insert
  • Daily checks of IGRT positioning accuracy as recommended in  AAPM TG-179 and TG-142
  • Optional tilting base for 6D couch QA
  • Tissue-equivalent bone structures for enhanced visibility in kV and MV images
  • Ceramic MV visible sphere at isocenter for easy Winston-Lutz testing
  • Automated analysis of EPID images with optional PTW  IsoCheck epid  software
  • Integrated with Track-it

Patient QA

Select the Detector insert for measurement-based dose verification of patient treatment plans.

  • Fast, accurate point dose measurements with different detector types
  • “Plug and Measure” convenience using detector  holders – no need to replace phantom or exchange inserts
  • Dose verification of non-coplanar treatment plans
  • Use the “Film” insert for high-resolution dose distribution measurements in a plane using radiochromic films.

STARCHECK

  • Array detector with 707 ionization chambers (STARCHECK maxi) and 527 ionization chambers (STARCHECK)
  • Fast, precise real-time beam scanning without water tank measurement
  • High resolution of 3 mm on the main axes and diagonals
  • Detector size: 0.05 cm³
  • Large field size coverage: 26 cm x 26 cm (STARCHECK), 40 cm x 40 cm (STARCHECK maxi)
  • Gold standard ionization chambers – no need for frequent recalibration
  • Expert analysis tools, e.g. profile comparison, protocol-based analysis, movie mode
  • Fully integrated with Track-it for automated reporting
  • Reproducible, quick and easy positioning of the STARCHECK with the Couchfix Positioning Tool
  • Compatible version for MR linacs available

UNIDOS Tango and UNIDOS Romeo Reference Class Electrometers

UNIDOS Interactive

Striking design. Exceptional performance. Impressive functionality.

UNIDOS Tango

The smart reference class electrometer

  • Intelligent
    UNIDOS Tango automates detector management and identification using Intelligent Detector Recognition. Simply scan the data matrix code on your calibration certificate or detector label with the built-in camera, and a new detector is added to the database or the right detector chosen for measurement.

    IDR is particularly useful for clinical sites with multiple electrometers and/or detectors in use as it increases efficiency and reduces data entry errors.

  • Connected
     With its built-in webserver and LAN interface, UNIDOS Tango provides full remote control capabilities. Change settings or start measurements conveniently from your PC, view results instantly on your tablet or smartphone.

    If you are looking for maximum comfort and flexibility in operation, then UNIDOS Tango is the instrument of choice for you.

  • Secondary standard
    UNIDOS Tango is a secondary standard reference class electrometer which meets and exceeds both IEC and IPEM performance requirements. With the best available resolution in the market (0.1 fA), it is the perfect choice for high-precision measurements, e.g., in small field dosimetry.

UNIDOS Romeo

The standard reference class electrometer

  • Highly functional
     UNIDOS Romeo is a high-precision reference class electrometer which provides the functionality you need for routine operation. Managing the built-in detector database is not fully automated, but much simplified with an intuitive user interface and ready-to-use detector templates.

    Choose UNIDOS Romeo if you have a smaller budget, but do not want to compromise on accuracy and performance.  

  • Standalone
     UNIDOS Romeo has been designed primarily for standalone use. It comes with an intuitive touchscreen interface, which gives you instant access to all important settings and options, making standalone operation very easy.

    With its user-friendly design, it is perfect for sites who want best-in-class measurement technology, but do not need multiple connectivity options.

  • State-of-the-art
    UNIDOS Romeo is a versatile reference class electrometer that exceeds IEC 60731 performance requirements. It comes with a resolution of 1 fA, which makes it a reliable tool for reference dose and quality assurance measurements across all major applications.

Farmer Ionization Chamber 30013 waterproof

Farmer® Ionization Chamber 30013 waterproof

Waterproof therapy chamber for reference dosimetry in high-energy photon, electron and proton beams

  • Acrylic wall, graphited
  • Aluminum central electrode
  • Waterproof
  • Sensitive volume 0.6 cm3, vented
  • Reference class in accordance with IEC 60731 and AAPM TG-51 Addendum

The 30013 Farmer chamber is the standard ionization chamber for reference dose measurements in radiation therapy.

Correction factors needed to determine absorbed dose to water or air kerma are published in the pertinent dosimetry protocols.

Its waterproof design allows the chamber to be used in water or solid state phantoms. The acrylic chamber wall ensures the ruggedness of the chamber.

EPID QC Phantom / epidSoft Software

Turnkey Solution for Portal Imaging QA

EPID QC Phantom has been designed to check and monitor the image quality of EPIDs used in high-energy photon beams. The versatile phantom provides a wide range of test elements to check all relevant quality parameters of MV imagers with a single beam in one image. The large field of view of 25 cm x 25 cm at isocenter allows excellent field coverage for an entire imager check.

With epidSoft  you can easily evaluate images acquired with the PTW EPID QC Phantom. Measure length and angle  at SAD  taking into account the DICOM RT Image scaling information.

A comprehensive set of parameters can be verified taking one image only: linearity, isotropy, noise, flatness, scaling, offset, rotation, distortion, low contrast and high contrast resolution (up to 0.33 lp/mm in a focal spot geometry) in horizontal, vertical and diagonal direction.

Customize your printouts and document the long-term imaging performance in compliance with DIN 6847-6 or AAPM TG-142.  

Semiflex 3D Ion Chamber 31021

  • Vented, waterproof, fully guarded – the ideal chamber for relative and reference dosimetry measurements in water, air or solid state phantoms
  • True 3D geometry – uniform response in any direction
  • Unique design – fast, accurate scanning in in-plane and cross-plane directions without tank rotation or change of detector setup
  • Easy horizontal or vertical mounting for high-resolution measurements in both radial and axial orientations
  • Reference-class ionization chamber with exceptional dosimetric characteristics – suitable for reference dosimetry following standard dosimetry protocols, e.g., IAEA TRS-398, AAPM TG-51
  • Small size (0.07 cm³), high spatial resolution – perfect for measurements in small and FFF fields down to a field size of 2.5 cm x 2.5 cm
  • Radioactive check device optionally available
Suitable for photon and electron dosimetry in multiple applications
 
  • LINAC Acceptance Testing
  • TPS Beam Data Commissioning
  • Clinical Reference Dosimetry
  • Point Dose Measurements
The New Reference Class

Semiflex 3D meets and  exceeds the performance requirements of a reference-class ionization chamber as laid out in AAPM TG-51 and IEC 60731:

  • Minimal polarity effect (< 0.4 % correction, < 0.5 % maximum variation)
  • Extremely low volume effect (est. ≤ 0.05 % correction in FFF field)
  • Excellent chamber settling (< 0.3 %)
  • Very low post-irradiation leakage – far below IEC 60731 requirements
  • Significantly reduced cable effects (< 200 fC / (Gy * cm))
  • Minimal chamber-to-chamber variation – reliable kQ and kS values

NOMEX Multimeter

  • All relevant X-ray parameters captured in one single shot
  • Modular, individual, easy-to-upgrade models for specific X-ray modalities: RAD/FLUDENTMAMCT, IGRT available
  • PC-based, ultrafast setup – ready to use, only one cable to connect
  • Fully automated medical device class IIb – all relevant ranges set up automatically
  • Exceeding IEC standard requirements: Dose accuracy within the RAD/FLU range typically ± 1.5%, within the MAM range ± 2.5% and kV accuracy within the RAD/FLU range typically ± 0.75% or ± 0.5 kV
  • Rotation-independent positioning in the central beam – no further alignment needed
  • Intuitive software, including one-click export of data and waveform charts to MS Excel® templates
  • Fully integrated with Track-it for long-term trend analysis

NOMEX Multimeter

  • Miniaturized multi-parameter measuring device compliant with IEC 61674 (passed the Type Approval Under German Law by the German National Metrology Institute, PTB)
  • Connection to a PC or alternatively to the NOMEX Dosemeter via USB
  • For measurements in RAD/FLU, DENT, CT, MAM (available qualities: Mo/30μmMo, Mo/25μmRh, Mo/0.25mmCu, W/0.7mmAl, W/50μmRh, W/50μmAg, W/0.3mmCu Rh/25μmRh, Rh/0.03mmAg, Rh/0.25mmCu, W/1.1mmTi)
  • Single exposure simultaneously captures: dose, dose rate, dose per pulse, pulses, frequency, irradiation time, tube voltage (kVpmax, kVpmean, PPV acc. to the algorithm of IEC 61676), total filtration, half value layer, together with waveforms for both kV and dose rate and optionally the mAs (invasively or non-invasively)
NOMEX® Software
 
  • Modifiable parameter displaying (view all parameters at a glance or just selected ones)
  • Statistic calculations (mean value, standard deviation, coefficient of variation) by simply marking the results of interest
  • Adjustable timer functions (start or stop delays) and waveform sampling
  • Data and waveform export directly to MS Excel (templates) or to Track-it
  • Software menu available in different languages (German, English, French, Spanish, Portuguese, Italian, Russian, Chinese, Japanese)
  • Individual multimeter models for specific X-ray modalities
  • Simultaneous measurement of all parameters with each model: dose, dose rate, dose per pulse, pulses, frequency, PPV, kVpmean, kVpmax, exposure time, HVL, total filtration, waveforms   
  • Invasive or non-invasive mAs measurement optionally available
  • Cost-effective – modular, easy to upgrade as needs grow