Dosimetry Equipment
Track-it QA data management platform

Key Features
- Web-based application for quick access to all your QA data from anywhere in your network using desktop or mobile devices
- Online or offline QA report processing, e.g., in treatment rooms without wireless network access
- User-defined protocol templates to customize Track-it to the specific needs of your QA workflows
- Full compliance with all major QA standards, including AAPM TG-142
- Traceable documentation of all steps in your QA workflow, such as data entry, modification and reporting
- Trend analysis over time and across multiple measurement or treatment devices with versatile display options
- Digital logbook to store and retrieve entries and attached service documents for your radiation devices, e.g., manuals, service reports or images
- Remote and on-site services for greater productivity right from the start.
QUICKCHECK webline

Key Features
- Suitable for all linear accelerators and radiation fields, including flattening filter free (FFF) radiation
- Standalone, truly wireless operation
- Fully automatic workflow using predefined worklists
- Integrated auto functions (start, stop, stand-by, shutdown, calendar)
- Immediate display of measurement results via large, full-color display and LED status indicators
- Gold standard ionization chamber technology
- Password-protected access
Supported QA Procedures
- X-ray output constancy
- Electron output constancy
- Photon beam profile constancy
- Electron beam profile constancy
- Electron beam energy constancy
Application Highlights
- Constancy check of all essential beam parameters in one go and at any gantry angle
- Built-in beam energy check
- Field sizes 10 x 10 and 20 x 20 cm²
- Automatic air density correction
- All major dosimetry protocols included
- Vendor-specific gantry mounts for rotational testing optionally available
RUBY Modular QA Phantoms

Key Features
Base phantom or head phantom. Multiple inserts. System QA. Linac QA. Patient QA.
System QA
Choose the “System QA” insert for comprehensive end-to-end testing with one single insert.
Key Features
- MRI visibility in all commonly used sequences (T1, T2 and FLAIR at 1.5 T) – no additional components required
- ICRU-based tissue-equivalent materials (brain, lung, bone) for verification of dose calculations at different tissue densities
- CT and MRI cavities for accurate verification of the CT/MRI image fusion algorithm of treatment planning systems
- Point dose measurements with different detector types using the same insert
Linac QA
Perform alignment checks of the entire system, including conventional as well as 6D couches, with the “Linac QA” insert.
Key Features
- System alignment and isocenter checks with one single insert
- Daily checks of IGRT positioning accuracy as recommended in AAPM TG-179 and TG-142
- Optional tilting base for 6D couch QA
- Tissue-equivalent bone structures for enhanced visibility in kV and MV images
- Ceramic MV visible sphere at isocenter for easy Winston-Lutz testing
- Automated analysis of EPID images with optional PTW IsoCheck epid software
- Integrated with Track-it
Patient QA
Select the “Detector” insert for measurement-based dose verification of patient treatment plans.
Key Features
- Fast, accurate point dose measurements with different detector types
- “Plug and Measure” convenience using detector holders – no need to replace phantom or exchange inserts
- Dose verification of non-coplanar treatment plans
Use the “Film” insert for high-resolution dose distribution measurements in a plane using radiochromic films.
Farmer Ionization Chamber 30013 waterproof

Key Features
Farmer® Ionization Chamber 30013 waterproof
Waterproof therapy chamber for reference dosimetry in high-energy photon, electron and proton beams
- Acrylic wall, graphited
- Aluminum central electrode
- Waterproof
- Sensitive volume 0.6 cm3, vented
- Reference class in accordance with IEC 60731 and AAPM TG-51 Addendum
The 30013 Farmer chamber is the standard ionization chamber for reference dose measurements in radiation therapy.
Correction factors needed to determine absorbed dose to water or air kerma are published in the pertinent dosimetry protocols.
Its waterproof design allows the chamber to be used in water or solid state phantoms. The acrylic chamber wall ensures the ruggedness of the chamber.
Semiflex 3D Ion Chamber 31021

Key Features
- Vented, waterproof, fully guarded – the ideal chamber for relative and reference dosimetry measurements in water, air or solid state phantoms
- True 3D geometry – uniform response in any direction
- Unique design – fast, accurate scanning in in-plane and cross-plane directions without tank rotation or change of detector setup
- Easy horizontal or vertical mounting for high-resolution measurements in both radial and axial orientations
- Reference-class ionization chamber with exceptional dosimetric characteristics – suitable for reference dosimetry following standard dosimetry protocols, e.g., IAEA TRS-398, AAPM TG-51
- Small size (0.07 cm³), high spatial resolution – perfect for measurements in small and FFF fields down to a field size of 2.5 cm x 2.5 cm
- Radioactive check device optionally available
Suitable for photon and electron dosimetry in multiple applications
- LINAC Acceptance Testing
- TPS Beam Data Commissioning
- Clinical Reference Dosimetry
- Point Dose Measurements
The New Reference Class
Semiflex 3D meets and exceeds the performance requirements of a reference-class ionization chamber as laid out in AAPM TG-51 and IEC 60731:
- Minimal polarity effect (< 0.4 % correction, < 0.5 % maximum variation)
- Extremely low volume effect (est. ≤ 0.05 % correction in FFF field)
- Excellent chamber settling (< 0.3 %)
- Very low post-irradiation leakage – far below IEC 60731 requirements
- Significantly reduced cable effects (< 200 fC / (Gy * cm))
- Minimal chamber-to-chamber variation – reliable kQ and kS values